???jsp.display-item.social.title??? |
![]() ![]() |
Please use this identifier to cite or link to this item:
https://tede.ufam.edu.br/handle/tede/10726
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.creator | Albuquerque, Celina de Araújo | - |
dc.creator.Lattes | http://lattes.cnpq.br/6563456050484783 | eng |
dc.contributor.advisor1 | Marques, André Augusto Franco | - |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/0881446518841907 | eng |
dc.contributor.advisor-co1 | Sponchiado Júnior, Emílio Carlos | - |
dc.contributor.advisor-co1Lattes | http://lattes.cnpq.br/6190247766651853 | eng |
dc.contributor.referee1 | Hanan, Aida Renée Assayag | - |
dc.contributor.referee2 | João, Mariana Mena Barreto Pivoto | - |
dc.date.issued | 2025-02-21 | - |
dc.identifier.citation | ALBUQUERQUE, Celina de Araújo. Análise das características de superfície e desvio apical promovido por instrumentos rotatórios após uso em canais simulados - Estudo in vitro. 2025. 61 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Amazonas, Manaus (AM), 2025. | eng |
dc.identifier.uri | https://tede.ufam.edu.br/handle/tede/10726 | - |
dc.description.resumo | O objetivo desse estudo foi comparar dois sistemas de instrumentação rotatória em canais curvos simulados, verificando suas características de superfície, desvio apical e o desgaste dos instrumentos após o uso. Foram selecionados 30 canais simulados, confeccionados em blocos transparentes de resina, padronizados com ângulo de curvatura de 32o, raio de curvatura de 3 milímetro (mm), 16mm de comprimento e 30 instrumentos endodônticos, divididos em dois grupos. No grupo 01, foram utilizados 15 instrumentos 25.06 do sistema Logic e no grupo 02, 15 instrumentos 25.06 do sistema VDW Rotate, utilizados uma única vez. Cada alargador foi analisado antes e após ao primeiro uso pelo Microscópio Eletrônico de Varredura (MEV), com aumento de 190x, verificando as características de superfície, em especial os defeitos do tipo rebarbas, em três áreas distintas: ponta, 2omm e 4omm, aquém da ponta, além de serem pesados em balança eletrônica analítica. Os canais simulados foram instrumentados a 0,5mm do comprimento de trabalho, com auxílio de motor endodôntico, em movimentos de vaivém, com irrigação de hipoclorito de sódio a 2,5%. Para o desvio apical, cada bloco de resina foi fotografado antes e após a instrumentação e as imagens sobrepostas para mensuração do desvio no 1o, 2o, 3o e 4o mm do terço apical. Os blocos foram pesados antes e após a instrumentação para verificação do desgaste após o preparo químico- mecânico. A análise estatística apontou diferença significante (p < 0,0001) em relação a pesagem dos instrumentos entre os grupos, antes e após a instrumentação. Não houve alterações significativas na pesagem dos blocos (p > 0,05). Todos os instrumentos apresentaram alterações nas características superficiais e as áreas dos defeitos de rebarbas apresentaram diferenças em determinados pontos, observando uma redução na extensão das rebarbas, além dos instrumentos VDW Rotate demonstrarem um acabamento superficial mais uniforme. Na análise do desvio apical, não foram observadas diferenças estatisticamente significantes (p > 0,05). Por fim, foi possível concluir que os sistemas rotatórios estudados apresentaram desempenho satisfatório durante a instrumentação dos canais radiculares e, apesar de alguns defeitos superficiais, os sistemas de NiTi tratados termicamente são atualmente uma opção segura e eficaz para o tratamento endodôntico. | eng |
dc.description.abstract | The aim of this study was to compare two rotary instrumentation systems in simulated curved canals, evaluating their surface characteristics, apical deviation, and instrument wear after use. A total of 30 simulated canals, manufactured in transparent resin blocks with standardized curvature angles of 32o, a curvature radius of 3 mm, and a length of 16 mm, were selected, along with 30 endodontic instruments divided into two groups. In Group 1, fifteen 25.06 instruments from the Logic system were used, while in Group 2, fifteen 25.06 instruments from the VDW Rotate system were employed, each used only once. Each instrument was analyzed before and after its first use using a Scanning Electron Microscope (SEM) at 190x magnification to assess surface characteristics, particularly the presence of burr-type defects, in three distinct areas: the tip, the 2nd mm, and the 4th mm from the tip. Additionally, the instruments were weighed using an analytical electronic balance. The simulated canals were instrumented 0.5 mm short of the working length with the aid of an endodontic motor, using a reciprocating motion and irrigated with 2.5% sodium hypochlorite. To evaluate apical deviation, each resin block was photographed before and after instrumentation, and the images were superimposed to measure deviation at the 1st, 2nd, 3rd, and 4th mm of the apical third. The blocks were weighed before and after instrumentation to assess wear after chemomechanical preparation. Statistical analysis revealed a significant difference (p < 0.0001) in instrument weight between the groups before and after instrumentation. However, no significant changes were observed in the weight of the resin blocks (p > 0.05). All instruments exhibited alterations in surface characteristics, and the burr defect areas varied at specific points, with a reduction in burr extension. Additionally, the VDW Rotate instruments demonstrated a more uniform surface finish. No statistically significant differences were found in apical deviation analysis (p > 0.05). In conclusion, the rotary systems studied demonstrated satisfactory performance during root canal instrumentation. Despite some superficial defects, thermally treated NiTi systems are currently a safe and effective option for endodontic treatment. | eng |
dc.format | application/pdf | * |
dc.thumbnail.url | https://tede.ufam.edu.br/retrieve/82083/DISS_CelinaAlbuquerque_PPGO.pdf.jpg | * |
dc.language | por | eng |
dc.publisher | Universidade Federal do Amazonas | eng |
dc.publisher.department | Faculdade de Odontologia | eng |
dc.publisher.country | Brasil | eng |
dc.publisher.initials | UFAM | eng |
dc.publisher.program | Programa de Pós-graduação em Odontologia | eng |
dc.rights | Acesso Aberto | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | pt_BR |
dc.subject | Instrumentos e aparelhos odontológicos | por |
dc.subject.cnpq | CIENCIAS DA SAUDE: ODONTOLOGIA | eng |
dc.title | Análise das características de superfície e desvio apical promovido por instrumentos rotatórios após uso em canais simulados - Estudo in vitro | eng |
dc.type | Dissertação | eng |
dc.subject.user | Endodontia | por |
dc.subject.user | Instrumentos odontológicos | por |
dc.subject.user | Preparo do canal radicular | por |
dc.subject.user | Microscopia eletrônica de varredura | por |
Appears in Collections: | Mestrado em Odontologia |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
DISS_CelinaAlbuquerque_PPGO.pdf | 25.9 MB | Adobe PDF | ![]() Download/Open Preview |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.