???jsp.display-item.social.title??? |
![]() ![]() |
Please use this identifier to cite or link to this item:
https://tede.ufam.edu.br/handle/tede/10963
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.creator | Azize, Inah Mota Araripe | - |
dc.creator.Lattes | http://lattes.cnpq.br/6232110337950400 | eng |
dc.contributor.advisor1 | Mateus, Rossato | - |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/7997306983184031 | eng |
dc.contributor.referee1 | Santos, João Libardoni Otacílio dos | - |
dc.contributor.referee2 | Freire Junior, Renato Campos | - |
dc.date.issued | 2025-04-08 | - |
dc.identifier.citation | AZIZE, Inah Mota Araripe. Efeitos do treinamento de marcha com o aprimoramento de um dispositivo de biofeedback visual sobre parâmetros da marcha de pacientes com doença de Parkinson. 2025. 61 f. Dissertação (Mestrado em Ciências da Saúde) - Universidade Federal do Amazonas, Manaus, 2025. | eng |
dc.identifier.uri | https://tede.ufam.edu.br/handle/tede/10963 | - |
dc.description.resumo | O objetivo deste estudo foi avaliar o efeito do biofeedback visual fornecido por uma tecnologia vestível como estratégia para o treinamento da marcha em pacientes com doença de Parkinson (DP). Para isso, utilizamos o design quase experimental de sujeito único. Fizeram parte do estudo três mulheres com diagnóstico de DP e características semelhantes da doença. Todos os participantes foram submetidos a 40 sessões de treinamento de marcha, sendo 10 sessões de Adaptação, 10 sessões de treinamento Controle “A”, 10 sessões de treinamento na fase de Intervenção “B” e 10 sessões de treinamento na fase de Retenção “A’ ”. Antes de iniciar cada uma das fases, realizou-se o Teste de Velocidade de Marcha de 10 Metros. As sessões de treinamento tiveram 15 minutos de duração, sempre na mesma velocidade definida na primeira sessão de treinamento da fase de controle “A”. O participante 01, na fase de Intervenção (B), recebeu feedbacks verbais de um terapeuta. Já o participante 02, na fase de Intervenção (B), recebeu biofeedbacks visuais oriundos do celular. O participante 03 realizou todas as 30 sessões de treinamento de marcha (A-B-A’) sem biofeedback. O biofeedback foi fornecido por sensores fixados na região dos tornozelos, que reconheceram os padrões de marcha realizados durante o aquecimento (1 minuto inicial) e consideraram esses valores como referência. Posteriormente, durante a parte principal do treinamento (14 min) da fase de intervenção, a cor indicada no celular considerou o comprimento do passo e o número de passos obtidos na calibração inicial (aumento no número de passos ou redução no comprimento do passo vermelho, aumento no comprimento do passo e redução no número de passos verde, manutenção no comprimento do passo e número de passos amarelo. O terapeuta, de posse dessas informações, forneceu feedback verbal para o participante 01. Enquanto isso, o participante 02 teve apenas biofeedback visual, precisando ele mesmo ajustar o padrão de marcha. Para avaliar os efeitos do tempo (A-B-A’) de cada participante utilizamos a Anova one-way (comparamos o número de passos e o comprimento de passos.). Para isso, empregamos o pacote estatístico software GraphPad Prism, versão 8.4.3, considerando um nível de significância de 5%. Nossos resultados indicaram que todas as participantes apresentaram melhora no teste de 10 MWT. Concluímos que o fornecimento de biofeedback, seja verbal, visual ou a ausência de feedback (grupo controle), não resultou em diferenças estatisticamente significativas nos parâmetros da marcha. No entanto, melhorias clínicas foram identificadas, sugerindo que essas intervenções podem influenciar positivamente o padrão de marcha dos pacientes com DP. | eng |
dc.description.abstract | The objective of this study was to evaluate the effect of visual biofeedback provided by a wearable technology as a strategy for gait training in patients with Parkinson’s disease (PD). For this purpose, we used a single-subject quasi-experimental design. Three participants with a PD diagnosis and similar disease characteristics took part in the study. All participants underwent 40 gait training sessions, including 10 Adaptation sessions, 10 Control training sessions (“A”), 10 training sessions in the Intervention phase (“B”), and 10 training sessions in the Retention phase (“A”). The training sessions lasted 20 minutes, always at the same speed defined in the first session of the Control phase (“A”). Participant 01, in the Intervention phase (B), received verbal feedback from a therapist. Participant 02, in the Intervention phase (B), received visual biofeedback from a mobile device. Participant 03 completed all 30 gait training sessions (A-B-A) without biofeedback. Biofeedback was provided by sensors attached to the ankle region, which recognized gait patterns performed during the warm-up (first 1 minute) and considered these values as a reference. Subsequently, during the main part of the training (14 min), gait parameters, such as step frequency, were compared to the reference values. Increases in frequency, relative to the reference values, were indicated by a red light. The therapist, in possession of this information, provided verbal feedback to participant 01.Meanwhile, participant 02 had only visual biofeedback, needing to adjust the gait pattern himself. To evaluate the effects of time (A-B-A) of each participant, we used one-way Anova (we compared the number of steps and the length of steps.). For this, we used the statistical software package GraphPad Prism, version 8.4.3, considering a significance level of 5%. Our results indicated that all participants showed improvement in the 10 MWT test. We conclude that the provision of biofeedback, whether verbal, visual or the absence of feedback (control group), did not result in statistically significant differences in gait parameters. However, clinical improvements were identified, suggesting that these interventions can positively influence the gait pattern of patients with PD. | eng |
dc.format | application/pdf | * |
dc.thumbnail.url | https://tede.ufam.edu.br/retrieve/85141/DISS_InahAzize_PPGCIS.pdf.jpg | * |
dc.language | por | eng |
dc.publisher | Universidade Federal do Amazonas | eng |
dc.publisher.department | Faculdade de Medicina | eng |
dc.publisher.country | Brasil | eng |
dc.publisher.initials | UFAM | eng |
dc.publisher.program | Programa de Pós-graduação em Ciências da Saúde | eng |
dc.rights | Acesso Aberto | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | - |
dc.subject | Doença de Parkinson | por |
dc.subject | Dispositivos Eletrônicos Vestíveis | por |
dc.subject | Tecnologias assistivas | por |
dc.subject.cnpq | CIENCIAS DA SAUDE | eng |
dc.title | Efeitos do treinamento de marcha com o aprimoramento de um dispositivo de biofeedback visual sobre parâmetros da marcha de pacientes com doença de Parkinson | eng |
dc.title.alternative | Effects of the use of a visual biofeedback device on gait parameters of patients with Parkinson's disease | eng |
dc.type | Dissertação | eng |
dc.subject.user | Reabilitação | por |
dc.subject.user | Tecnologias assistivas | por |
dc.subject.user | Doença de Parkinson | por |
Appears in Collections: | Mestrado em Ciências da Saúde |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
DISS_InahAzize_PPGCIS.pdf | 1.06 MB | Adobe PDF | ![]() Download/Open Preview |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.