???item.export.label??? ???item.export.type.endnote??? ???item.export.type.bibtex???

Please use this identifier to cite or link to this item: https://tede.ufam.edu.br/handle/tede/4097
Full metadata record
DC FieldValueLanguage
dc.creatorSouza, Samir Noronha de-
dc.creator.Latteshttp://lattes.cnpq.br/3378233487908869por
dc.contributor.advisor1Garrido, Angela Delfina Bittencourt-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/7821317409789400por
dc.date.issued2014-02-24-
dc.identifier.citationSOUZA, Samir Noronha de. Avaliação de um novo protocolo para remoção de retentores metálicos por meio do ultrassom em dentes multirradiculares. 2014. 76 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Amazonas, Manaus, 2014.por
dc.identifier.urihttp://tede.ufam.edu.br/handle/tede/4097-
dc.description.resumoEste trabalho visa avaliar in vitro um novo protocolo para remoção de retentores intrarradiculares em dentes multirradiculares aplicando a vibração ultrassônica. Quarenta molares inferiores foram tratados endodonticamente para receber retentores intrarradiculares fundidos, sendo distribuídos em 4 grupos: GI – controle sem fenda; GII – controle com fenda; GIII – aplicação ultrassom em núcleo sem fenda; GIV – aplicação de ultrassom em núcleo com fenda. Após a fixação dos retentores com cimento de fosfato de zinco, a vibração ultrassônica foi realizada no grupo III durante 1 minuto, sendo 15 segundos em cada face e no grupo IV 15 segundos nas faces vestibular e lingual, e 30 segundos dentro da fenda, totalizando 1 minuto. Em seguida, os corpos-de-prova foram submetidos ao teste de tração na Máquina Universal de Ensaio com velocidade de 1 mm/min. A força de tração máxima necessária para a remoção do retentor intrarradicular foi registrada em Newton e os dados foram submetidos à análise estatística ANOVA e Tukey-Kramer. Os resultados mostraram haver diferença estatística significante entre os grupos testados (GI – 234,34 N; GII – 201,67 N; GIII – 139,57 N; GIV – 83,23 N), sendo a menor média da força de tração obtida quando se aplicou vibração ultrassônica sobre o núcleo com fenda (p<0,05). Conclui-se que a realização de uma fenda no núcleo e a aplicação ultrassônica em todas as faces e dentro da fenda promoveu a redução da força necessária para a remoção de retentores intrarradiculares metálicos fixados com fosfato de zinco em dentes multirradiculares.por
dc.description.abstractThe purpose of this paper is to evaluate in vitro a new protocol for intra-radicular posts removal for multi-radicular teeth by applying ultrasonic vibration. Forty lower molars were endodontically treated in order to receive cast posts and cores, being distributed in 4 groups: GI – control without slot; GII – control with slot; GIII – ultrasound application in core without slot; GIV – ultrasound application in core with slot. After the cast posts fixation using zinc phosphate cement, the ultrasonic vibration was applied in group III for 1 minute, dividing 15 seconds on each surface and in group IV 15 seconds on facial and lingual surface, and 30 seconds inside the slot totaling 1 minute. Thereafter, samples were subjected to tensile test in Universal Assay Machine at the speed of 1mm/min. The maximum tensile strength needed for intra-radicular posts removal was registered in Newton and its data were subjected to statistical analysis ANOVA e Tukey-Kramer. The results presented statistically significant differences between the tested groups (GI – 234,34 N; GII – 201,67 N; GIII – 139,57 N; GIV – 83,23 N), with the smallest average of the tensile strength obtained when ultrasonic vibration on the core slotted applied (p<0,05). It is concluded that the implemantation of a slot in the core and ultrasonic application on all the surfaces and inside the slot caused a reduction of force required for removing cast posts and cores fixed with zinc phosphate in multi-radicular teeth.eng
dc.description.sponsorshipCAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superiorpor
dc.formatapplication/pdf*
dc.thumbnail.urlhttp://200.129.163.131:8080//retrieve/10952/Disserta%c3%a7%c3%a3o%20-Samir%20Noronha%20de%20Souza.pdf.jpg*
dc.languageporpor
dc.publisherUniversidade Federal do Amazonaspor
dc.publisher.departmentFaculdade de Odontologiapor
dc.publisher.countryBrasilpor
dc.publisher.initialsUFAMpor
dc.publisher.programPrograma de Pós-graduação em Odontologiapor
dc.rightsAcesso Abertopor
dc.subjectPino metálico fundidopor
dc.subjectRemoção de pino intrarradicularpor
dc.subjectUltrassompor
dc.subjectPost removaleng
dc.subjectUltrasoundeng
dc.subject.cnpqCIÊNCIAS DA SAÚDE: ODONTOLOGIApor
dc.titleAvaliação de um novo protocolo para remoção de retentores metálicos por meio do ultrassom em dentes multirradicularespor
dc.typeDissertaçãopor
Appears in Collections:Mestrado em Odontologia

Files in This Item:
File Description SizeFormat 
Dissertação -Samir Noronha de Souza.pdfDissertação -Samir Noronha de Souza1.4 MBAdobe PDFThumbnail

Download/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.