???item.export.label??? ???item.export.type.endnote??? ???item.export.type.bibtex???

Please use this identifier to cite or link to this item: https://tede.ufam.edu.br/handle/tede/8396
Full metadata record
DC FieldValueLanguage
dc.creatorPérez, Maria Tereza Martins-
dc.creator.Latteshttp://lattes.cnpq.br/1431995883647240eng
dc.contributor.advisor1Manzato, Lizandro-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/0677617028146410eng
dc.contributor.referee1Augusto, Carolina Rocha-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/3526941665114920eng
dc.contributor.referee3Carvalhal, Cintia Iara Oda-
dc.contributor.referee3Latteshttp://lattes.cnpq.br/8821156090928265eng
dc.date.issued2021-07-29-
dc.identifier.citationPÉREZ, Maria Tereza Martins. Estudo da incorporação de nanocelulose no cimento odontológico ionômero de vidro, 2021. 62 f. Dissertação (Mestrado em Ciência e Engenharia de Materiais) - Universidade Federal do Amazonas, Manaus (AM), 2021.eng
dc.identifier.urihttps://tede.ufam.edu.br/handle/tede/8396-
dc.description.resumoO cimento de ionômero de vidro convencional restaurador (ionômero de vidro) é um material restaurador de uso versátil na odontologia. Apresenta excelentes propriedades como liberação de flúor e adesão a estrutura dentária, entretanto não apresenta boa resistência mecânica. Essa limitação não permite o seu uso em áreas de grande esforço mastigatório. A nanocelulose tem sido usada como agente de reforço em diversos tipos de materiais. O seu uso na área biomédica e odontológica deve-se a sua capacidade de reforçar a matriz de compósitos. A nanocelulose pode ser extraída na forma de nanocristais (CNC). Assim, o objetivo deste trabalho foi avaliar se a adição de CNC melhora as propriedades mecânicas do ionômero de vidro. Foram confeccionados os corpos de prova, dividas em grupos contendo a porcentagem em peso de CNC (0,2%, 0,4% e 0,6%) e um grupo controle (sem modificações). As técnicas de caracterização foram FTIR e DRX. O FTIR demonstrou que não há diferença das ligações químicas entre o GC e os grupos com adição. Foram avaliadas as propriedades mecânicas do material após 24h pelos ensaios de resistência à compressão e resistência à tração por compressão diametral. Os resultados foram tratados e plotados, obtendo os gráficos de tensão X deformação, a média de cada grupo pontos da máxima deformação, onde o GC apresentou média e desvio-padrão de 91,52 (3,36) MPa; 0,2% de 109,11 (10,51) MPa; 0,4% de 93,19 (1,97) MPa e 0,6% 76,63 (8,49) MPa. Os dados foram analisados por meio da análise de variância (ANOVA) e teste de Tukey apresentaram diferenças significantes entre os grupos. O grupo com adição de 0,2% apresentou média de 109,11 (± 10,51) MPa, sendo o melhor grupo, um aumento de 19% quando comparado ao grupo controle. O grupo com adição de 0,4% um aumento de 1,8% e o de 0,6% uma diminuição de 16%.eng
dc.description.abstractConventional glass ionomer cement is a versatile restorative material in dentistry. It has excellent properties such as fluoride release and adhesion to tooth structure, however it does not have good mechanical resistance. This limitation does not allow its use in areas of great masticatory effort. A nanocellulose has been used as a reinforcing agent in different types of materials. Its use in the biomedical and dental field is due to its ability to reinforce the composite matrix. A nanocellulose can be extracted in the form of nanocrystals (CNC). Thus, the aim of this work was to evaluate whether the addition of CNC improves the mechanical properties of the material. The specimens were made, divided into groups containing the percentage by weight of CNC (0.2%, 0.4% and 0.6%) and a control group (without modifications). The characterization techniques were FTIR and DRX. The active FTIR that there is no difference in bindings between the GC and the groups with addition. They were evaluated as mechanical properties of the cement after 24 hours by compressive strength and tensile strength by diametrical compression tests. The results were treated and plotted, obtaining the stress X strain graphs, the mean of each group of points of maximum strain, where the CG presented mean and standard deviation of 91.52 (3.36) MPa; 0.2% of 109.11 (10.51) MPa; 0.4% of 93.19 (1.97) MPa and 0.6% 76.63 (8.49) MPa. Data were dissipated through analysis of variance (ANOVA) and significant differences between groups. The group with the addition of 0.2% mean presentation of 109.11 (± 10.51) MPa, being the best group, an increase of 19% when compared to the control group. The group with the addition of 0.4% an increase of 1.8% and the 0.6% group a decrease of 16%.eng
dc.description.sponsorshipFAPEAM - Fundação de Amparo à Pesquisa do Estado do Amazonaseng
dc.formatapplication/pdf*
dc.thumbnail.urlhttps://tede.ufam.edu.br/retrieve/48083/Dissertacao_MariaP%c3%a9rez_PPGCEM.pdf.jpg*
dc.languageporeng
dc.publisherUniversidade Federal do Amazonaseng
dc.publisher.departmentFaculdade de Tecnologiaeng
dc.publisher.countryBrasileng
dc.publisher.initialsUFAMeng
dc.publisher.programPrograma de Pós-graduação em Ciência e Engenharia de Materiaiseng
dc.rightsAcesso Aberto-
dc.subjectCimentos dentários de ionômero de vidropor
dc.subjectMateriais dentáriospor
dc.subject.cnpqENGENHARIAS: ENGENHARIA DE MATERIAIS E METALURGICA: MATERIAIS NAO METALICOSeng
dc.titleEstudo da incorporação de nanocelulose no cimento odontológico ionômero de vidroeng
dc.typeDissertaçãoeng
dc.subject.userIonômero de Vidropor
dc.subject.userNanocristais de Celulosepor
dc.subject.userResistência à Compressãopor
dc.subject.userDrxpor
dc.subject.userFtirpor
Appears in Collections:Mestrado em Ciência e Engenharia de Materiais

Files in This Item:
File Description SizeFormat 
Dissertacao_MariaPérez_PPGCEM.pdf1.9 MBAdobe PDFThumbnail

Download/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.